In the operation of subway tunnels, in order to ensure the comfort and safety of passengers and the normal operation of equipment, it is necessary to dynamically switch the ventilation mode according to different working conditions. As an advanced control method, variable frequency speed regulation technology plays a key role in subway tunnel fans, and can accurately realize the dynamic switching of ventilation modes to meet the ventilation needs in various situations.

Subway tunnels usually have multiple ventilation modes, such as normal operation ventilation, blocking ventilation and fire ventilation. During normal operation ventilation, it is necessary to provide an appropriate amount of fresh air according to factors such as passenger flow and train operation frequency to maintain the air quality and temperature in the tunnel. Blocking ventilation is to provide sufficient ventilation volume to ensure the safety of passengers and equipment when the train is blocked in the tunnel. Fire ventilation requires that smoke and toxic gases be quickly discharged when a fire occurs to create conditions for personnel evacuation and fire rescue.

Variable frequency speed regulation technology is to adjust the speed of the motor by changing the frequency of the motor power supply. For subway tunnel fan motors, when the frequency increases, the motor speed increases, and the fan's air volume and air pressure increase; conversely, when the frequency decreases, the motor speed slows down, and the air volume and air pressure decrease. By precisely controlling the frequency of the inverter output, the fan motor speed can be precisely adjusted to meet the air volume requirements under different ventilation modes.

In order to achieve dynamic switching of ventilation modes, various sensors are installed in subway tunnels to monitor environmental parameters and train operation status. For example, temperature sensors can monitor the air temperature in the tunnel in real time, smoke sensors can detect whether smoke is present, pressure sensors can measure changes in air pressure in the tunnel, and train position sensors can determine the running position and status of the train. These sensors transmit the collected data to the control system, which judges the current working conditions based on preset thresholds and logic to determine whether the ventilation mode needs to be switched and which mode to switch to.

The control system of the subway tunnel ventilation system usually adopts a programmable logic controller (PLC) or a distributed control system (DCS). When the control system receives the data from the sensor, it will compare and analyze it with the preset parameters. For example, when the temperature sensor detects that the temperature in the tunnel exceeds the normal operating set value and the train is running normally, the control system determines that the ventilation volume needs to be increased, so it sends instructions to the inverter to increase the power supply frequency of the fan motor, speed up the fan speed, increase the ventilation volume, and switch from the normal operating ventilation mode to the enhanced ventilation mode. In emergency situations such as blockage or fire, the control system will quickly issue instructions according to the corresponding logic, switch the ventilation mode to the corresponding emergency mode, and adjust the fan speed to meet the ventilation requirements under special working conditions.

The inverter accurately adjusts the output frequency according to the instructions sent by the control system, thereby realizing smooth adjustment of the fan motor speed. In normal operating ventilation mode, it may be necessary to adjust the fan speed in a small range according to different time periods and passenger flow, and accurately control the ventilation volume, so as to ensure ventilation effect and avoid energy waste. In emergency modes such as blockage ventilation or fire ventilation, it is necessary to quickly increase the fan speed to the set emergency speed to provide a large amount of ventilation in a short time. Through variable frequency speed regulation technology, subway tunnel fans can quickly and accurately switch between different ventilation modes and realize precise control of ventilation volume, effectively ensuring environmental safety and personnel comfort in subway tunnels.

In subway tunnel fans, variable frequency speed regulation technology realizes dynamic switching of ventilation modes through collaborative work with sensors and control systems. It can accurately adjust the fan speed and ventilation volume according to the actual working conditions in the tunnel, meet the ventilation needs in different situations, and provide strong guarantee for the safe and comfortable operation of the subway. With the continuous development of technology, the application of variable frequency speed regulation technology in subway tunnel ventilation systems will be more perfect, further improving the reliability and efficiency of subway operations.
×